Airwende Heat pump 15 kW R32 Split

Discover the new level of efficiency: Model AWHP-15SPAT-R2B1

Rely on the latest generation of temperature control with the AWHP-15SPAT-R2B1 - a heat pump that does not compromise on performance and environmental awareness.

15.5 kW heat output
Eligible

Increase the energy efficiency of your heating and cooling system with the AWHP-15SPAT-R2B1 heat pump. With the environmentally friendly refrigerant R32, high performance and a maximum heat output of 15.5 kW, it offers optimum temperature regulation. The system is reliable and suitable for domestic and commercial applications.

  • Maximum heat output: 15.5 kW to fulfil the most diverse requirements of private households and companies.
  • Energy efficiency: Outstanding COP value of up to 5.0 and EER of up to 5.1, for cost-saving operation.
  • Robust compressor: Twin Rotary compressor ensures a long service life and reliable performance.
  • Quiet operation: Low noise development with 40 dB(A) inside and 57 dB(A) outside for a quiet working and living atmosphere.
  • Environmentally friendly refrigerant: Use of R32, which has less impact on global warming and improves the ecological balance.
  • Simple installation: Compact dimensions and well thought-out design facilitate integration into existing systems.
Airwende Wärmepumpe 15 kW R32 Split

€ 10,476 plus VAT.

Efficiency class A+++
Eligible
EPR certificate
CE labelling
TÜV-tested
Product information
Technical specifications
Airwende R32 series

Technical overview

The heat pump model AWHP-15SPAT-R2B1 is a powerful solution for modern heating and cooling systems. The unit operates with a 380-420 V power supply and a 50 Hz three-phase current, using the environmentally friendly refrigerant R32. This heat pump offers a maximum heating capacity of 15.5 kW.

Power efficiency

The efficiency of the appliance is represented by the COP value (Coefficient of Performance) and EER value (Energy Efficiency Ratio). In heating mode, the heat pump achieves a COP value of up to 5.0 and in cooling mode an EER of up to 5.1, which indicates high energy efficiency in operation. The cooling capacity is variable and ranges between 7.2 kW and 18.5 kW.

Operating parameters

The heat pump is designed for an operating range of -25 to 43 °C, which means that it also works reliably in varying ambient temperatures. The installation requires a minimum floor area of 6.2 m² for both operational readiness and storage.

Compressor and refrigerant

At the heart of the heat pump is a Twin Rotary compressor, which is known for its durability and efficiency. With a refrigerant charge of 2.6 kg and an air flow of 6200 m³/h, the system ensures optimised heat transfer and even temperature distribution.

Noise emission and water reservoir

With a noise level of 40 dB(A) indoors and 57 dB(A) outdoors, noise levels remain moderate.

Dimensions and weight

The compact dimensions of the indoor module (750x500x300 mm) and the outdoor module (1085x400x1450 mm) make it easy to position the heat pump. The weight distribution of 42 kg for the indoor module and 120 kg for the outdoor module is designed for installation and maintenance.

Notes

The information on this model has been provided with care, but specifications may change without prior notice. It is recommended to check the actual specifications directly on the device.

Article no.AWHP-15SPAT-R2B1
Refrigerant (type / quantity)R32 / 2.6 kg
Max. heat output (DB 7°C / WB 6°C)15.5 kW
Power supply / frequency380-420 V / 50 Hz
Noise levelIndoor unit40 dB (A)
Outdoor unit57 dB (A)

Heating mode

Ambient temperature (DB/WB): 7/6 ℃
Water temperature (on/off): 30/35 ℃
C.O.P4.6 W/W
Ambient temperature (DB/WB): 7/6 ℃
Water temperature (on/off): 40/45 ℃
C.O.P3.5 W/W

Cooling mode

Ambient temperature (DB/WB): 35/24 ℃
Water temperature (on/off): 23/18 ℃
E.E.R3.7 W/W
Ambient temperature-25~43 ℃
Minimum system water temperature (heating/cooling)20/7 ℃
Device nameAWHP-15SPAT-R2B1
Power supply/refrigerant
Voltage/frequency/phase380-420V/50Hz/3
RefrigerantR-32
Heat output
Under conditions Water inlet/outlet temperature 30°C/35°C, ambient temperature DB 7°C/WB 6°C
Maximum heat output (1)15.5 kW
C.O.P. (1)4,6
Heat output min./max.(1)7.3 kW / 15.5 kW
C.O.P. min./max.(1)4,5 / 5,0
Heat output
Under conditions Water inlet/outlet temperature 40°C/45°C, ambient temperature DB 7°C/WB 6°C
Maximum heat output (2)14.4 kW
C.O.P. (2)3,5
Heat output min./max.(2)6.6 kW / 14.4 kW
C.O.P. Min./Max.(2)3,5 / 3,7
Cooling capacity
Under conditions Water inlet/outlet temperature 23°C/18°C, ambient temperature DB 35°C/WB 24°C
Maximum cooling capacity (3)18.5 kW
E.E.R. (3)3,7
Cooling capacity min./max.(3)7.2 kW / 18.5 kW
E.E.R. Min./Max.(3)3,7 / 5,1
Cooling capacity
Under conditions Water inlet/outlet temperature 12°C/7°C Ambient temperature DB 35°C/WB 24°C
Maximum cooling capacity (4)13 kW
E.E.R. (4)3,0
Cooling capacity min./max.(4)10.3 kW / 13 kW
E.E.R. Min./Max.(4)3,0 / 3,2
General data
Circuit breaker25 A
Working range of the ambient temperature-25~43 °C
Min. system water temperature (heating / cooling)20 / 7 °C
Minimal space for installation, operation and storage6,2 m²
Minimum surface area of the pipe6,2 m²
Maximum operating pressure High pressure4.2 MPa
Maximum operating pressure Low pressure1.2 MPa
Compressor
Type/NumberTwin Rotary / 1
Refrigerant quantityR32 / 2.6kg
Fan
Quantity2
Air flow rate6200 m³/h
Noise level (sound power)
Inside/outside40/57 dB(A)
Water cooler Heat exchanger
TypePlate heat exchanger
Pressure drop26 kPa
Water connections
Connection typeG5/4"
Permitted water flow Min./Max.0.50/0.72/0.93 L/s
Dimensions (LxWxH)
Indoor unit750x500x300 mm
Outdoor unit1085x400x1450 mm
Weight
Indoor unit42 kg
Outdoor unit120 kg