The AWHP-15MPAT-R2B1: your reliable partner for year-round climate comfort. First-class performance meets sustainable technology.
Redefine efficiency with the AWHP-15MPAT-R2B1. This heat pump offers impressive heating and cooling performance that adapts perfectly to your needs - whatever the weather. With the environmentally friendly refrigerant R32, you are helping to protect the environment.
Up to 15.5 kW heating output and 18.5 kW cooling output for every season.
Use the environmentally friendly refrigerant R32 with high efficiency.
Reliable operation at temperatures from -25 °C to 43 °C, ideal for compact rooms.
Low noise levels and easy maintenance ensure convenience.
€ 9,892 plus VAT.
The AWHP-15MPAT-R2B1 heat pump is characterised by a remarkable heating capacity of up to 15.5 kW, maintaining impressive performance even at lower operating conditions. The appliance offers excellent adaptability with a wide range of minimum and maximum output values to ensure that you can enjoy optimum comfort both in the coldest months and during transitional periods.
Environmentally conscious cooling and heating
With a C.O.P. (Coefficient of Performance) of 4.6 under standard conditions, this model is highly efficient in heating mode. In cooling mode, it boasts an energy efficiency ratio (E.E.R.) of up to 3.7, which indicates that the pump offers a high yield of cooling capacity for every proportion of energy used. These figures emphasise the commitment to energy efficiency and cost savings during operation.
Optimised for a wide range of environments
The heat pump adapts flexibly to different ambient temperatures, from an icy -25 °C to a summery 43 °C, proving its reliability across a wide range of climatic conditions. With a small footprint for installation, it is also a space-saving solution that is suitable for smaller technical rooms.
Sustainable technology in use
The environmentally friendly refrigerant R32 used in this system has a lower global warming potential than many conventional refrigerants and therefore contributes to environmental protection. In addition, the efficient Twin Rotary compressor not only ensures quiet operation, but also long-term reliable performance.
Designed for user comfort
The appliance emphasises its claim to user-friendliness with a clear and easy-to-use operating concept. A quiet operating noise promotes comfort in both commercial and private environments, while the robust design and low maintenance requirements represent a long-term investment in your well-being.
Combining performance, efficiency and user comfort, the AWHP-15MPAT-R2B1 heat pump offers an advanced solution for modern heating and cooling requirements.
Article no. | AWHP-15MPAT-R2B1 | |
Refrigerant (type / quantity) | R32 / 2.55 kg | |
Max. heat output (DB 7°C / WB 6°C) | 15.5 kW | |
Power supply / frequency | 380-420 V / 50 Hz | |
Noise level | Indoor unit | 40 dB (A) |
Outdoor unit | 57 dB (A) |
Ambient temperature (DB/WB): 7/6 ℃ Water temperature (on/off): 30/35 ℃ | ||
C.O.P | 4.6 W/W | |
Ambient temperature (DB/WB): 7/6 ℃ Water temperature (on/off): 40/45 ℃ | ||
C.O.P | 3.5 W/W |
Ambient temperature (DB/WB): 35/24 ℃ Water temperature (on/off): 23/18 ℃ | ||
E.E.R | 3.7 W/W |
Ambient temperature | -25~43 ℃ | |
Minimum system water temperature (heating/cooling) | 20/7 ℃ |
Power supply and refrigerant | |
---|---|
Power supply | 380-420V/50Hz/3 phases |
Refrigerant | R32 |
Heat output | |
Max. heat output | 15.5 kW |
Min./Max. Heating output (under standard conditions (1)) | 7.3/15.5 kW |
Min./Max. Heating output (at lower conditions (2)) | 6.6/14.4 kW |
Coefficient of performance - C.O.P. (at standard conditions (1)) | 4,6 |
Coefficient of performance - C.O.P. (at lower conditions (2)) | 3,5 |
Cooling capacity | |
Max. Cooling capacity | 18.5 kW |
Min./max. cooling capacity (at standard conditions (3)) | 7.2/18.5 kW |
Min./max. cooling capacity (at lower conditions (4)) | 10.3/13 kW |
Energy efficiency ratio - E.E.R. (at standard conditions (3)) | 3,7 |
Energy efficiency ratio - E.E.R. (at lower conditions (4)) | 3,0 |
Electrical data | |
Circuit breaker | 25 A |
Operating conditions | |
Operating ambient temperature range | -25 to 43 °C |
Minimum system water temperature (heating / cooling) | 20 / 7 °C |
Minimal space for installation, operation and storage | 6,2 m² |
Maximum operating high pressure | 4.2 MPa |
Maximum operating low pressure | 1.2 MPa |
Refrigerant compressor | |
Type | Twin Rotary - 1 |
Quantity/system | R32 / 2.55 kg |
Noise level | |
Sound power inside/outside | 40 / 57 dB(A) |
Heat exchanger water side | |
Type | Plate heat exchanger |
Water-side pressure drop | 26 kPa |
Piping Connection | G5/4" |
Flow rate | |
Permissible water flow rate | L/s |
Min./Rated./Max. | 0.5/0.72/0.93 L/s |
Dimensions and weight | |
Interior (LxWxH) | 570x550x260 mm |
Outside (LxWxH) | 1085x400x1450 mm |
Net weight inside | 25 Kg |
Net weight outside | 130 kg |
Please note that the heating and cooling capacity values as well as the C.O.P. and E.E.R. values were measured under specific operating conditions, which are explained in the footnotes of the technical data sheet. These conditions are | |
Heating condition (1) | |
Water temperature inlet/outlet | 30°C/35°C |
Ambient temperature | DB 7°C/WB 6°C |
Heating condition (2) | |
Water temperature inlet/outlet | 40°C/45°C |
Ambient temperature | DB 7°C/WB 6°C |
Cooling condition (3) | |
Water temperature inlet/outlet | 23°C/18°C |
Ambient temperature | DB 35°C/WB 24°C |
Cooling condition (4) | |
Water temperature inlet/outlet | 12°C/7°C |
Ambient temperature | DB 35°C/WB 24°C |
DB stands for "Dry Bulb" (dry bulb temperature) and WB for "Wet Bulb" (wet bulb temperature). This information is important in order to correctly assess the performance of the heat pump under real conditions. |