Airwende Heat pump 12 kW R32 Split

The AWHP-12SPAS-R2B1 heat pump - efficiency meets innovation.

Increase your well-being with the AWHP-12SPAS-R2B1 - the heat pump that combines performance and sustainability.

11.6 kW heat output
Eligible

Find out how our latest AWHP-12SPAS-R2B1 heat pump reduces your energy costs and protects the climate at the same time. With its dual function, it offers outstanding performance in both heating and cooling, and does so with whisper-quiet operation. This model sets new standards in terms of efficiency and comfort for your home or business.

Top performance: Heating up to 11.6 kW (C.O.P. up to 4.9) and cooling up to 9.8 kW (E.E.R. up to 3.9).

Economic efficiency and environmental friendliness: Energy-efficient technology and environmentally friendly R32 refrigerant reduce operating costs and support climate targets.

Adaptability: Robust design for temperatures from -25 to 43 °C and flexible installation thanks to compact dimensions.

Pleasant acoustics: Quiet operating modes with 45 dB(A) inside and 52 dB(A) outside ensure peace and comfort.

Ease of installation: Intuitive installation with a small footprint.

Airwende Wärmepumpe 12 kW R32 Split

€ 8,005 plus VAT.

Efficiency class A+++
Eligible
EPR certificate
CE labelling
TÜV-tested
Product information
Technical specifications
Airwende R32 series

Energy efficiency that sets standards

Our AWHP-12SPAS-R2B1 heat pump is equipped with leading energy efficiency ratings and delivers maximum heating and cooling performance while minimising energy consumption. With an impressive maximum heating output value of 11.6 kW and a Cooling Operating Performance (C.O.P.) of up to 4.9, this model guarantees efficient heat recovery even at low temperatures.

Customised to your needs

The system adapts flexibly to different conditions and withstands a wide operating temperature range of -25 to 43 °C and a minimum system water temperature for heating and cooling of 20/7 °C. Whether on cold winter nights or hot summer days, this heat pump delivers constant performance.

State-of-the-art cooling technology

In cooling mode, the heat pump scores with a maximum cooling output of 9.8 kW and an Energy Efficiency Ratio (E.E.R.) of up to 3.9. These figures speak for themselves and offer you efficient cooling and a pleasant room climate.

Quiet operation

With a noise level of just 45 dB(A) indoors and 52 dB(A) outdoors, the heat pump is as quiet as a whisper. Your everyday life remains undisturbed while you benefit from the pleasant warmth or coolness.

Robust and reliable

Equipped with a Twin Rotary compressor and a filling weight of 1.8 kg R32 refrigerant, this model not only offers outstanding durability, but also contributes to environmental friendliness. The solid construction guarantees a long service life and reliable operation.

Easy to install

Thanks to the compact dimensions of the indoor unit (750x500x300 mm) and the outdoor unit (1165x370x845 mm) and a well thought-out design, installation of the heat pump is uncomplicated and space-saving.

Environmentally conscious and sustainable

Choose the AWHP-12SPAS-R2B1 heat pump and invest in a sustainable future. Low energy consumption and environmentally friendly refrigerant R32 ensure environmentally conscious heating and cooling operation.

Discover the efficiency and comfort of the AWHP-12SPAS-R2B1 - your solution for an optimum indoor climate that perfectly combines economic and ecological requirements.

Article no.AWHP-12SPAS-R2B1
Refrigerant (type / quantity)R32 / 1.8 kg
Max. heat output (DB 7°C / WB 6°C)11.6 kW
Power supply / frequency220-240 V / 50 Hz
Noise levelIndoor unit45 dB (A)
Outdoor unit52 dB (A)

Heating mode

Ambient temperature (DB/WB): 7/6 ℃
Water temperature (on/off): 30/35 ℃
C.O.P4.3 W/W
Ambient temperature (DB/WB): 7/6 ℃
Water temperature (on/off): 40/45 ℃
C.O.P3.4 W/W

Cooling mode

Ambient temperature (DB/WB): 35/24 ℃
Water temperature (on/off): 23/18 ℃
E.E.R3.9 W/W
Ambient temperature-25~43 ℃
Minimum system water temperature (heating/cooling)20/7 ℃
Device nameAWHP-12SPAS-R2B1
Power supply/refrigerant
Voltage/frequency/phase220-240V/50Hz/1
RefrigerantR-32
Heat output
Under conditions Water inlet/outlet temperature 30°C/35°C, ambient temperature DB 7°C/WB 6°C
Maximum heat output (1)11.6 kW
C.O.P. (1)4,3
Heat output min./max.(1)5.5 kW / 11.6 kW
C.O.P. min./max.(1)4,3 / 4,9
Heat output
Under conditions Water inlet/outlet temperature 40°C/45°C, ambient temperature DB 7°C/WB 6°C
Maximum heat output (2)11.2 kW
C.O.P. (2)3,4
Heat output min./max.(2)4.9 kW / 11.2 kW
C.O.P. Min./Max.(2)3,4 / 3,6
Cooling capacity
Under conditions Water inlet/outlet temperature 23°C/18°C, ambient temperature DB 35°C/WB 24°C
Maximum cooling capacity (3)9.8 kW
E.E.R. (3)3,9
Cooling capacity min./max.(3)7.0 kW / 9.8 kW
E.E.R. Min./Max.(3)4,05 / 3,9
Cooling capacity
Under conditions Water inlet/outlet temperature 12°C/7°C Ambient temperature DB 35°C/WB 24°C
Maximum cooling capacity (4)8.3 kW
E.E.R. (4)2,7
Cooling capacity min./max.(4)4.9 kW / 8.3 kW
E.E.R. Min./Max.(4)2,87 / 3,7
General data
Circuit breaker25 A
Working range of the ambient temperature-25~43 °C
Min. system water temperature (heating / cooling)20 / 7 °C
Minimal space for installation, operation and storage3,1 m²
Minimum surface area of the pipe3,1 m²
Maximum operating pressure High pressure4.2 MPa
Maximum operating pressure Low pressure1.2 MPa
Compressor
Type/NumberTwin Rotary / 1
Refrigerant quantityR32 / 1.8kg
Fan
Quantity1
Air flow rate3150 m³/h
Noise level (sound power)
Inside/outside45/52 dB(A)
Water cooler Heat exchanger
TypePlate heat exchanger
Pressure drop26 kPa
Water connections
Connection typeG1"
Permitted water flow Min./Max.0.4/0.57/0.74 L/s
Dimensions (LxWxH)
Indoor unit750x500x300 mm
Outdoor unit1165x370x845
Weight
Indoor unit39 kg
Outdoor unit75 kg