The AWHP-12MPAS-R2B1 combines sustainable innovation with unrivalled efficiency. Discover a heat pump that is designed for every need while protecting the environment.
Immerse yourself in the world of highly efficient heat pump technology with the AWHP-12MPAS-R2B1. Find out how our advanced system can revolutionise your heating and cooling needs - with minimum energy consumption and maximum comfort. With its quiet operation and adaptability to various climate conditions, our heat pump sets standards for private households and businesses alike. Build on sustainable efficiency without compromising on performance or environmental friendliness.
€ 7,362 plus VAT.
Powerful and energy-efficient Our AWHP-12MPAS-R2B1 heat pump sets new standards in terms of performance and energy efficiency. With a maximum heat output of 11.6 kW and an impressive coefficient of performance (COP) of up to 4.3, this model offers outstanding heat generation, creating optimum conditions for both private households and business customers. This high efficiency means that for every unit of electricity consumed, a greater amount of heat is generated, significantly reducing operating costs.
Optimised for all climatic conditions With a wide operating temperature range of -25 to 43 °C, this heat pump is equipped for any weather conditions. It works reliably even in extreme outdoor temperatures and ensures pleasant indoor temperatures all year round, making it an ideal system for regions with highly variable climates.
Low-noise operation Despite its high performance, the pump is remarkably quiet with a noise level of 45/52 dB(A). This makes it an unobtrusive addition to any environment, whether in the hustle and bustle of everyday life or in the quiet atmosphere of your own home.
Environmentally friendly thanks to advanced refrigerant By using the refrigerant R32, which has a lower Global Warming Potential (GWP) than conventional refrigerants, the heat pump makes an important contribution to environmental protection. At the same time, it guarantees outstanding thermal efficiency and lower CO2 emissions.
Compact design and easy handling The compact design of the indoor and outdoor units makes installation and maintenance simple and space-saving. The clear lines and modern appearance blend harmoniously into any building.
Conclusion The AWHP-12MPAS-R2B1 is not only an example of technological innovation, but also of our commitment to quality and sustainability. It is an investment characterised by low operating costs, high performance and environmentally friendly operation. Whether for domestic or commercial use, this heat pump stands for reliability and efficiency.
Article no. | AWHP-12MPAS-R2B1 | |
Refrigerant (type / quantity) | R32 / 1.8 kg | |
Max. heat output (DB 7°C / WB 6°C) | 11.6 kW | |
Power supply / frequency | 220-240 V / 50 Hz | |
Noise level | Indoor unit | 45 dB (A) |
Outdoor unit | 52 dB (A) |
Ambient temperature (DB/WB): 7/6 ℃ Water temperature (on/off): 30/35 ℃ | ||
C.O.P | 4.3 W/W | |
Ambient temperature (DB/WB): 7/6 ℃ Water temperature (on/off): 40/45 ℃ | ||
C.O.P | 3.4 W/W |
Ambient temperature (DB/WB): 35/24 ℃ Water temperature (on/off): 23/18 ℃ | ||
E.E.R | 3.9 W/W |
Ambient temperature | -25~43 ℃ | |
Minimum system water temperature (heating/cooling) | 20/7 ℃ |
General information | |
---|---|
Name | AWHP-12MPAS-R2B1 |
Power supply / refrigerant | 220-240/50/1 - R32 |
Heating mode | |
Maximum heat output | 11.6 kW |
COP in heating mode (1) | 4,3 |
Heating capacity min./max. (1) | 5.5/11.6 kW |
Heating power consumption min./max. (1) | 1077/2683 W |
COP min/max (1) | 4,3/4,9 |
Maximum heat output at low temperature (2) | 11.2 kW |
Heating capacity min./max. (2) | 4.9/11.2 kW |
Heating power consumption min./max. (2) | 1401/3263 W |
COP min./max. at low temperature (2) | 3,4/3,6 |
Cooling mode | |
Maximum cooling capacity | 9.8 kW |
Energy efficiency ratio (EER) in cooling mode (3) | 3.9 |
Cooling capacity min/max (3) | 7.0/9.8 kW |
Cooling power consumption min./max. (3) | 1728/2510 W |
EER min/max (3) | 4.05/3.9 |
Cooling capacity min/max (4) | 4.9/8.3 kW |
COP in cooling mode (4) | 2.7 |
Cooling power consumption min./max. (4) | 1358/2610 W |
EER min/max (4) | 2,87/3,7 |
Physical properties | |
Circuit breaker | 25 A |
Working temperature range | -25 to 43 °C |
Minimum system water temperature (heating / cooling) | 20 / 7 °C |
Minimum area for installation, operation and storage | 3.1 m² |
Minimum pipe laying area | 3.1 m² |
Maximum operating high pressure | 4.2 MPa |
Maximum operating low pressure | 1.2 MPa |
Compressor | Twin Rotary - 1 |
Refrigerant | R32 1.8 kg |
Air flow rate | 3150 m³/h |
Noise development | |
Noise level (sound power) inside/outside | 45/52 dB(A) |
Water-side heat exchanger | |
Type | Plate heat exchanger |
Water pressure drop | 26 kPa |
Pipe connections | G1" |
Permissible water flow rate | 0.40/0.57/0.74 L/s |
Dimensions and weight | |
Net dimensions (LxWxH) indoor/outdoor unit | 570×550×260 mm / 1165×370×845 mm |
Net weight indoor/outdoor unit | 25 Kg / 85 Kg |
Please note that the specifications given may be subject to change. Always refer to the rating plate on the appliance for the exact specification. |